Thursday, 10 August 2017

Better Control of Airflow with Volume Control Dampers

You better know that it is really impossible to tolerate the temperature without having a perfect HVAC system. There are several parts related to the good working of the system. Volume control dampers are one among them and are developed to provide positive control and to balance the pressure and air flow in the HVAC system.

Get the best

Now you better know the importance of dampers for your system and the next questions is where to get the best. You never like to compromise on the quality of the product to assure safe working of ventilation systems. KAD Air Conditioning really knows your intentions and hence provides you dampers in several formats or adjustments systems to meet the needs of most of the installations.

These dampers work with opposed blade action supported by better aerodynamics to provide perfect balancing and control of air flow rates. Manually operated volume dampers are basically supplied with lockable quadrant that helps you to turn the same to a motor operated damper without the requirement of any additional parts or components.

Why select KAD Air Conditioning

Quality really matters! Yes, this is the reason why you have to get the volume dampers from KAD, the mastering minds in designing and developing different dampers including fire dampers, duct dampers, volume control dampers, aluminum duct dampers, motorized damper and other related accessories.

Important features

Volume dampers from the house of KAD are designed from 100 MM to 1200 MM for a single section. If the requirement is more than that, then the dampers will be developed in multiple sections using single or multiple drives in accordance with the requirement. Dampers come with pre punched holes to make the installation so easy.

Exclusive features

KAD provides motorized volume control damper that is well said for its application, high tensile strength, long service life, specific design, etc. All of the products are manufactured in accordance with the international standards to assure maximum comfort and satisfaction for the end users.

It is your time

Now it is your time to take the decision. KAD really knows what you exactly need and is always ready to serve the best in volume control dampers.

Friday, 6 May 2016

Time to Know more about the Different Types of Variable Air Volume System

At present, you cannot afford to miss out the importance of variable air volume system, which is growing at a fast pace. Whenever you are talking about air conditioning, this forms an integral part of the AC.  Some of the reliable companies are going to offer you with the best types of air volume system, depending on the requirement of clients. Some of the best examples, which you need to be aware of, are RVP C, RZ P, ZPC, RVP C T and RVP P T.

Know more about RVP C

Before you proceed further to know more about variable air volume system, you should check out on the available options. RVP C is one of the best examples available, dealing with volume flow controlling regulations within a chosen set point. This product is known for its factory parameterization, as coming in accordance with the client’s prime request. Moreover, this product comprises of higher regulation precision without any maintenance from your side. Some of the options available here are a master-slave, constant, insulated casing, Modbus, LONWORKS, and MF.

Get down to RVP P


Want to know more about some of the other types of variable air volume system? In case, the answer is yes, you can always shift your notice towards RVP P. This is considered as a volume flow control regulations, which are associated with a given set point. Moreover, you will come across factory parameterization, as per the requirements of clients. On the other hand, you can come across high regulation precision without any maintenance. Some of the available options are a master-slave mod, constant mod, insulated casing, Modbus, LONWORKS, and MF. 

Choose the best one

If you are looking for the best variable units, you need to get help from reputed firms first. There are reliable firms, which are now offering vast sections of air volume systems. If you want to know more about other parts of AC, you will get to know more about them from the same sections. Consult an expert before investing money in any of the units. You will also receive some valuable information on displacement units, as well.

Monday, 11 January 2016

The Importance of Fire Rated Access Doors & Other Maintenance Tips for Fire Dampers

Fire dampers are an inescapably important part of a residential or commercial building’s HVAC system. Fire dampers have a fusible link attached to them that melt when the temperature inside the duct goes above the acceptable limit, which closes the fire damper down, thus preventing the uncontrolled spread of the flame.

Fire dampers need to be tested and maintained thoroughly. The initial test of the fire damper is done at the time of its installation, after which it is again performed the following year. According to regional laws and regulations, the fire damper can be tested every 4 - 6 years after the second test. In order to properly test, maintain, and repair these dampers, the presence of fire rated access doors is of paramount importance. These must be fitted in the duct system by air conditioning companies in UAE at the time of installing the ducts in the building.

Fire dampers are essential enough to the safety of the building’s inhabitants and property that any detection of improper functioning must immediately be met with repairs and/or replacements of faulty parts, like springs or crookedly attached panels.

The dampers and fire rated access doors must also be maintained regularly, checking for any signs of physical damage and alien objects and particles that could obstruct its proper functioning. Missing small parts and proper labelling is also a priority.

During testing, ensure that the fire damper is able to close completely to its intended extent.

If the fusible link is found to be damaged it should immediately be replaced by the same type of link. The parameters of the new fusible link, such as size, temperate range, and load limit should be double checked to ensure that they are the same as the link that is being replaced.

These measures are very important because a fire can occur at any time, and if one does occur while a fire damper is waiting to be repaired or is overdue on a maintenance check, not only will the fire spread uninhibited and damage a lot of property and take potential lives, but it will also leave the building owner’s highly accountable for negligent behavior.